Beranda » Products » Omron 3G3MX2-A4055-V1

Omron 3G3MX2-A4055-V1

  • account_circle
  • calendar_month 28/02/2025
  • visibility 59
  • comment 0 komentar
  • label

Omron Automation 3G3MX2-A4055-V1 MX2 Inverter Drive 5.5(Heavy Load)kW,7.5(Light Load)kW,3-Phase In,380 to 480V ac

Brand:
SKU: 3G3MX2-A4055-V1 Category: Tag: Brand:

Description

Specifically created for your application, the MX2 was developed to harmonize advanced motor and machine control. Thanks to its advanced design and algorithms, the MX2 provides smooth control down to zero speed, plus precise operation for cyclic operations and torque control capability in open loop. By using the standard MX2 series functionality and communication option boards, the MX2 IP54 is the perfect choice for your standalone inverter solutions. Features:

  • Up to 15 kW
  • 200% starting torque
  • Torque control in open loop
  • Double rating VT 120%/1 min and CT 150%/1 min
  • IM & PM motor control
  • Safety conforming to ISO13849-1 Category3 performance level PLD
  • Built-in Logic programming
  • Positioning functionality
  • Integrated at Omron machine Automation solution
  • Fieldbus communications: EtherCAT, Modbus, DeviceNet, Profibus, CompoNet, MECHATROLINK-II and EtherNet/IP

Specification

Function nameSpecifications
Enclosure ratings *1Open type (IP20)
Control methodPhase-to-phase sinusoidal modulation PWM
Output frequency range *20.10 to 400 Hz (or 580 Hz in the high-frequency mode; restrictions apply)
Frequency precision *3Digital command: ±0.01% of the max. frequency, Analog command: ±0.2% of the max. frequency (25±10°C)
Frequency setting resolutionDigital setting: 0.01 Hz, Analog setting: One-thousandth of the maximum frequency
Voltage/Frequency characteristicsV/f characteristics (constant/reduced torque)Sensorless vector control, V/f control with speed feedback
Overload current ratingHeavy load rating (CT): 150%/60 s Light load rating (VT): 120%/60 s
Instantaneous overcurrent protection200% of the value of heavy load rating (CT)
Acceleration/Deceleration time0.01 to 3600 s (linear/curve selection), acceleration/deceleration 2 setting available
Carrier frequency adjustment range2 to 15 kHz (with derating)
Starting torque200%/0.5 Hz (sensorless vector control)
External DC injection brakingStarts at a frequency lower than that in deceleration via the STOP command, at a value set lower than that during operation, or via an external input. (Level and time settable).
 Protective functionsOvercurrent, overvoltage, undervoltage, electronic thermal, temperature error, ground fault overcur- rent at power-on status, rush current prevention circuit, overload limit, incoming overvoltage, exter- nal trip, memory error, CPU error, USP error, communication error, overvoltage suppression during deceleration, protection upon momentary power outage, emergency cutoff, etc.
Frequency settingsDigital OperatorExternal analog input signal: 0 to 10 VDC/4 to 20 mA, Modbus communication (Modbus-RTU)
RUN/STOP commandDigital OperatorExternal digital input signal (3-wire input supported), Modbus communication (Modbus-RTU)
Multi-function input *47 points (Functions can be selected from among 68)
Analog input *52 points (Voltage FV terminal: 10 bits/0 to 10 V, Current FI terminal: 10 bits/4 to 20 mA)
Pulse input1 point (RP terminal: 32 kHz max., 5 to 24 VDC)
Multi-function output *42 points (P1 and P2, Functions can be selected from among 47)
Relay output *41 point (SPDT contact (MC, MA, MB), Functions can be selected from among 47)
Analog output (Frequency monitor)*61 point (AM terminal: Voltage 10 bits/0 to 10 V) (Frequency, current selectable)
Pulse output1 point (MP terminal: 32 kHz max., 0 to 10 V)
RS-422RJ45 connector (for Digital Operator)
RS-485Control circuit terminal block, Modbus communication (Modbus-RTU)
USBUSB1.1, mini-B connector
  Other functionsAVR function, V/f characteristics switching, upper/lower limit, 16-step speeds, starting frequency adjustment, jogging operation, carrier frequency adjustment, PID control, frequency jump, analog gain/bias adjustment, S shape acceleration/deceleration, electronic thermal characteristics, level adjustment, restart function, torque boost function, fault monitor, soft lock function, frequency conversion display, USP function, motor 2 control function, UP/DWN, overcurrent control function, etc.
Ambient operating temperature *7-10 to 50°C (However, derating is required).
Ambient storage temperature-20°C to 65°C
Ambient operating humidity20% to 90% RH (with no condensation)
Vibration resistance5.9 m/s2 (0.6G), 10 to 55 Hz
Application environmentAt a maximum altitude of 1,000 m; indoors (without corrosive gases or dust)
EtherCAT Communication Unit3G3AX-MX2-ECT
CompoNet Communication Unit3G3AX-MX2-CRT-E
DeviceNet Communication Unit3G3AX-MX2-DRT-E

Datasheet

Additional information

Brand

Omron

Can't Find the Product?
Request Custom Quotation
Nama
Nama PT, CV atau Badan Usaha Lainnya
Nomor Whatsapp
Apabila unit tidak terdaftar di website atau lebih dari 1 item
PPN
No, thank you. I do not want.
100% secure your website.
expand_less