Beranda » Products » Schneider LC1G330KUEN

Schneider LC1G330KUEN

  • account_circle
  • calendar_month 28/02/2025
  • visibility 46
  • comment 0 komentar
  • label

Schneider Electric TeSys F LC1G330 Contactor, 100 → 250 V ac/dc Coil, 3-Pole, 440 A, 1 NO + 1 NC

Brand:
SKU: LC1G330KUEN Category: Tag:

Description

TeSys Giga high power contactor, 3 poles (3 NO) suitable for category AC-3 applications up to 330A 200kW@440V, equipped with 100-250V AC/DC wide band low consumption electronic coil and embedded highly reliable 1NO+1NC auxiliary contact block (17V 1mA). Designed for demanding applications with maximum operating rates up to 500 cycles per hour and environments up to 60°C. It’s built with high reliability delivering mechanical durability up to 8 million cycles. Contact Wear Diagnosis (CWD) is a standard function, It continuously monitors and provide feedback through healthy and alarm conditions by an LED indicator. It is possible to replace switching module (main contacts), control module enhancing contactor life with simple maintenance activities. Front accessible main power connections are with bolted connection and control connections by push-in terminals for easy and quick assembly. It provides IP2x protection from front face with optional terminal shrouds conforming to IEC 60529 and VDE 0106. It can cover -25°C to 60°C operation ambient air temperature and directly mounted on plate, with no derating up to 3000m altitude. Contactor can be installed in three quadrants of vertical plane, and OLR could be directly mounted below contactor. The dimensions are 225mm x 140mm x 226mm (H x W x D), compact size enables panel space savings. Multi standards certified (CB, CCC, cULcs, CE, UKCA marking,CE) and Green Premium compliant (RoHs/Reach). Unique QR code provides quick access to complete product data.

Specification

Main
RangeTeSys
Range of productTeSys Giga
Product or component typeContactor
Device short nameLC1G
Contactor applicationPower switching
Motor control
Utilisation categoryAC-1
AC-3
AC-3e
AC-4
AC-5a
AC-5b
AC-6a
AC-6b
AC-8a
AC-8b
DC-1
DC-3
DC-5
Poles description3P
[Ue] rated operational voltage<= 1000 V AC 50/60 Hz
<= 460 V DC
[Ie] rated operational current440 A (at <40 °C) at <= 1000 V AC-1
330 A (at <60 °C) at <= 440 V AC-3
[Uc] control circuit voltage100…250 V AC 50/60 Hz
100…250 V DC
Control circuit voltage limitsOperational: 0.8 Uc Min…1.1 Uc Max (at <60 °C)
Drop-out: 0.1 Uc Max…0.45 Uc Min (at <60 °C)
Complementary
[Uimp] rated impulse withstand voltage8 kV
overvoltage categoryIII
[Ith] conventional free air thermal current440 A (at 40 °C)
Rated breaking capacity2940 A at 440 V
[Icw] rated short-time withstand current2.65 kA – 10 s
1.8 kA – 30 s
1.3 kA – 1 min
0.9 kA – 3 min
0.75 kA – 10 min
Associated fuse rating400 A aM at <= 440 V for motor
250 A aM at <= 690 V for motor
500 A gG at <= 690 V
Average impedance0.000144 Ohm
[Ui] rated insulation voltage1000 V
Power dissipation per pole30 W AC-1 – Ith 440 A
16 W AC-3 – Ith 330 A
Compatibility codeLC1G
Pole contact composition3 NO
Auxiliary contact composition1 NO + 1 NC
Motor power kW90 kW at 230 V AC 50/60 Hz (AC-3e)
160 kW at 400 V AC 50/60 Hz (AC-3e)
160 kW at 415 V AC 50/60 Hz (AC-3e)
185 kW at 440 V AC 50/60 Hz (AC-3e)
200 kW at 500 V AC 50/60 Hz (AC-3e)
220 kW at 690 V AC 50/60 Hz (AC-3e)
185 kW at 1000 V AC 50/60 Hz (AC-3e)
90 kW at 230 V AC 50/60 Hz (AC-3)
160 kW at 400 V AC 50/60 Hz (AC-3)
160 kW at 415 V AC 50/60 Hz (AC-3)
200 kW at 440 V AC 50/60 Hz (AC-3)
200 kW at 500 V AC 50/60 Hz (AC-3)
220 kW at 690 V AC 50/60 Hz (AC-3)
185 kW at 1000 V AC 50/60 Hz (AC-3)
90 kW at 230 V AC 50/60 Hz (AC-4)
160 kW at 400 V AC 50/60 Hz (AC-4)
160 kW at 415 V AC 50/60 Hz (AC-4)
185 kW at 440 V AC 50/60 Hz (AC-4)
200 kW at 500 V AC 50/60 Hz (AC-4)
220 kW at 690 V AC 50/60 Hz (AC-4)
185 kW at 1000 V AC 50/60 Hz (AC-4)
Motor power hp100 hp at 200/208 V 60 Hz
125 hp at 230/240 V 60 Hz
250 hp at 460/480 V 60 Hz
300 hp at 575/600 V 60 Hz
Irms rated making capacity3830 A at 440 V
Coil technologyBuilt-in bidirectional peak limiting
Safety reliability levelB10d = 400000 cycles contactor with nominal load conforming to EN/ISO 13849-1
B10d = 3000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Mechanical durability8 Mcycles
inrush power in VA (50/60 Hz, AC)700 VA
inrush power in W (DC)645 W
hold-in power consumption in VA (50/60 Hz, AC)15.0 VA
hold-in power consumption in W (DC)9.1 W
Operating time40…70 ms closing
15…50 ms opening
Maximum operating rate600 cyc/h AC-3
600 cyc/h AC-3e
300 cyc/h AC-1
150 cyc/h AC-4
Connections – terminalsPower circuit: bar 2 – busbar cross section: 32 x 10 mm
Power circuit: lugs-ring terminals 1 185 mm²
Power circuit: bolted connection
Control circuit: push-in 1 0.2…2.5 mm² – cable stiffness: solid stranded without cable end
Control circuit: push-in 1 0.25…2.5 mm² – cable stiffness: flexible with cable end
Control circuit: push-in 2 0.5…1.0 mm² with cable end
Control circuit: push-in 0.75…2.5 mm² – cable stiffness: solid stranded without cable end
Control circuit: push-in 0.75…2.5 mm² – cable stiffness: flexible with cable end
Connection pitch45 mm
Mounting supportPlate
StandardsEN/IEC 60947-4-1
EN/IEC 60947-5-1
UL 60947-4-1
CSA C22.2 No 60947-4-1
JIS C8201-4-1
JIS C8201-5-1
IEC 60335-1:Clause 30.2
IEC 60335-2-40:Annex JJ
UL 60335-1
UL 60335-2-40:Annex JJ
Product certificationsCB Scheme
CCC
cULus
EAC
CE
UKCA
EU-RO-MR by DNV-GL
Tightening torque35 N.m
Height225 mm
Width140 mm
Depth226 mm
Net weight7 kg
Environment
IP degree of protectionIP2X front face with shrouds conforming to IEC 60529
IP2X front face with shrouds conforming to VDE 0106
Ambient air temperature for operation-25…60 °C
Ambient air temperature for storage-60…80 °C
Mechanical robustnessVibrations 5…300 Hz 2 gn contactor open
Vibrations 5…300 Hz 4 gn contactor closed
Shocks 10 gn 11 ms contactor open
Shocks 15 gn 11 ms contactor closed
ColourDark grey
Protective treatmentTH
Permissible ambient air temperature around the device-40…70 °C at Uc