Beranda » Products » Schneider LTMEV40BD

Schneider LTMEV40BD

  • account_circle
  • calendar_month 28/02/2025
  • visibility 50
  • comment 0 komentar
  • label

Brand:
SKU: LTMEV40BD Category: Tag:

Description

TeSys T is a motor management system that provides full motor monitoring, control, and protection when used with short circuit protection and a contactor. TeSys T manages most critical processes while reducing downtime and increasing productivity. TeSys T is a flexible system that integrates seamlessly into your automation system through five major communication protocols. TeSys T predicts what will happen in the process, as it accurately monitors current, voltage, and power over a wide range. TeSys T has a number of components that increase the flexibility of the system. This expansion module adds functionalities to the TeSys T controller. It adds voltage mesurement between phases up to 690 V nominal and 4 additional inputs. Module has 4 discrete logic inputs. 24 VDC is used to power the module. Module has the following certifications: UL, CSA NOM, ATEX, BV, EAC, RINA, LROS, DNV, ABS, GL, KERI, RMRoS, C-Tick and CCC.

Specification

Main
RangeTeSys
product nameTeSys T
Device short nameLTME
Product or component typeExtension module
Device applicationEquipment monitoring and control
Range compatibilityTeSys TeSys T LTMR motor controller
SupplyVia the controller
Complementary
[Ui] rated insulation voltage690 V conforming to EN/IEC 60947-1
690 V conforming to CSA C22.2 No 14
690 V conforming to UL 508
[Uimp] rated impulse withstand voltage6 kV current or voltage measurement circuit conforming to EN/IEC 60947-4-1
0.8 kV supply, inputs and outputs conforming to EN/IEC 60947-4-1
Logic input number4
Input current7 mA
Current state 0 guaranteedLogic input: < 5 V and <= 15 mA for 5 ms
Current state 1 guaranteedLogic input: < 15 V and 2…15 mA for 15 ms
maximum output switching frequency2 Hz
maximum operating rate1800 cyc/h
Contacts type and compositionWithout
Metering typeVoltage U21, U32, U13, V1, V2, V3
Imbalance voltage
Frequency
Calculated active and reactive energy (+/- W.h, +/- VAR.h)
Reactive power Q, Q1, Q2, Q3
Power factor
Active power P, P1, P2, P3
Measurement accuracy1 % voltage (100…830 V)
3 % power factor
5 % active and reactive power
overvoltage categoryIII
Connection pitch5.08 mm
Connections – terminalsControl circuit: connector 1 cable(s) 0.25…2.5 mm² (AWG 24…AWG 14) flexible with cable end
Control circuit: connector 1 cable(s) 0.2…2.5 mm² (AWG 24…AWG 14) flexible without cable end
Control circuit: connector 1 cable(s) 0.25…2.5 mm² (AWG 24…AWG 14) flexible without cable end
Control circuit: connector 1 cable(s) 0.2…2.5 mm² (AWG 24…AWG 14) solid without cable end
Control circuit: connector 2 cable(s) 0.2…1 mm² (AWG 24…AWG 14) flexible with cable end
Control circuit: connector 2 cable(s) 0.2…1.5 mm² (AWG 24…AWG 14) flexible without cable end
Control circuit: connector 2 cable(s) 0.5…1.5 mm² (AWG 24…AWG 14) flexible without cable end
Control circuit: connector 2 cable(s) 0.2…1 mm² (AWG 24…AWG 14) solid without cable end
Tightening torqueControl circuit: 0.5…0.6 N.m flat screwdriver 3 mm
pollution degree3
Electromagnetic compatibilityElectrostatic discharge, 3, 8 kV air, 6 kV contact, conforming to EN/IEC 61000-4-2
Fast transients immunity test (other circuits), level 3, 2 kV, conforming to EN/IEC 61000-4-4
Fast transients immunity test (on supply and relay outputs), level 4, 4 kV, conforming to EN/IEC 61000-4-4
Conducted RF disturbances, 10 V, conforming to EN/IEC 61000-4-6
Control circuit: surges (common mode), 1 kV, conforming to EN/IEC 61000-4-5
Control circuit: surges (serial mode), 1 kV, conforming to EN/IEC 61000-4-5
Communication: surges (common mode), 2 kV, conforming to EN/IEC 61000-4-5
Voltage inputs: surges (serial mode), 2 kV, conforming to EN/IEC 61000-4-5
Voltage inputs: surges (common mode), 4 kV, conforming to EN/IEC 61000-4-5
Width45 mm
Height61 mm
Depth120.7 mm
Net weight0.21 kg
Compatibility codeLTME
Environment
StandardsIEC 60947-4-1
UL 508
EN 60947-4-1
IACS E10
CSA C22.2 No 14
Product certificationsUL
NOM
ATEX
BV
CSA
EAC
RINA
LROS (Lloyds register of shipping)
DNV
ABS
GL
KERI
RMRoS
C-Tick
CCC
IP degree of protectionIP20
Protective treatment12 x 24 hour cycles conforming to EN/IEC 60068-2-30
48 h conforming to EN/IEC 60070-2-11
TH conforming to EN/IEC 60068
Fire resistance650 °C conforming to EN/IEC 60695-2-12
960 °C conforming to UL 94
Ambient air temperature for operation-20…60 °C
Ambient air temperature for storage-40…80 °C
Operating altitude<= 2000 m without derating
Mechanical robustnessShocks half sine wave acceleration: 15 Gn for 11 ms conforming to EN/IEC 60068-2-27
Vibrations mounted on symmetrical rail: 1 Gn, 5…300 Hz conforming to EN/IEC 60068-2-6
Vibrations plate mounted: 4 Gn, 5…300 Hz conforming to EN/IEC 60068-2-6

Datasheet

Additional information

Brand

Schneider

Can't Find the Product?
Request Custom Quotation
Nama
Nama PT, CV atau Badan Usaha Lainnya
Nomor Whatsapp
Apabila unit tidak terdaftar di website atau lebih dari 1 item
PPN
No, thank you. I do not want.
100% secure your website.
expand_less