| Appendant operation agent (Ex ia): | No |
| Appendant operation agent (Ex ib): | No |
| Basic device: | Yes |
| Category according to EN 954-1: | None |
| Degree of protection (IP): | IP20 |
| Depth: | 72mm |
| ETIM Class: | Logic module |
| ETIM Group: | PLC’s |
| Expandable: | Yes |
| Expansion device: | No |
| Explosion safety category for dust: | None |
| Explosion safety category for gas: | None |
| Front build in possible: | No |
| Height: | 90mm |
| IO link master: | No |
| Number of analogue inputs: | 4 |
| Number of analogue outputs: | 0 |
| Number of digital inputs: | 12 |
| Number of digital outputs: | 6 |
| Number of HW-interfaces industrial Ethernet: | 0 |
| Number of HW-interfaces other: | 3 |
| Number of HW-interfaces parallel: | 0 |
| Number of HW-interfaces RS-232: | 0 |
| Number of HW-interfaces RS-422: | 0 |
| Number of HW-interfaces RS-485: | 0 |
| Number of HW-interfaces serial TTY: | 0 |
| Number of HW-interfaces USB: | 0 |
| Number of HW-interfaces Wireless: | 0 |
| Number of interfaces PROFINET: | 0 |
| Performance level acc. EN ISO 13849-1: | None |
| Rack-assembly possible: | No |
| Radio standard Bluetooth: | No |
| Radio standard GPRS: | No |
| Radio standard GSM: | No |
| Radio standard UMTS: | No |
| Radio standard WLAN 802.11: | No |
| Rail mounting possible: | Yes |
| Redundancy: | No |
| SIL according to IEC 61508: | None |
| Suitable for safety functions: | No |
| Supply voltage DC: | 20.4 – 28.8V |
| Supporting protocol for ASI: | No |
| Supporting protocol for AS-Interface Safety at Work: | No |
| Supporting protocol for CAN: | No |
| Supporting protocol for Data-Highway: | No |
| Supporting protocol for DeviceNet: | No |
| Supporting protocol for DeviceNet Safety: | No |
| Supporting protocol for EtherNet/IP: | No |
| Supporting protocol for Foundation Fieldbus: | No |
| Supporting protocol for INTERBUS: | No |
| Supporting protocol for INTERBUS-Safety: | No |
| Supporting protocol for KNX: | No |
| Supporting protocol for LON: | No |
| Supporting protocol for MODBUS: | No |
| Supporting protocol for other bus systems: | Yes |
| Supporting protocol for PROFIBUS: | No |
| Supporting protocol for PROFINET CBA: | No |
| Supporting protocol for PROFINET IO: | No |
| Supporting protocol for PROFIsafe: | No |
| Supporting protocol for SafetyBUS p: | No |
| Supporting protocol for SERCOS: | No |
| Supporting protocol for SUCONET: | No |
| Supporting protocol for TCP/IP: | No |
| Switching current: | 8A |
| Voltage type of supply voltage: | DC |
| Wall mounting/direct mounting: | Yes |
| Width: | 107.5mm |
| With display: | No |
| With optical interface: | No |
| With relay output: | Yes |
| With timer: | Yes |